H CHEK, INC. RADON TEST KIT LABORATORY REPORT
|
|
|
Client Information:
Jane Smith
3535 E Wier Avenue, Suite 2
Phoenix, AZ 85040
e-mail: jsmith@cox.net
|
Property Tested:
3535 E. Wier Avenue
Suite 2
Phoenix, AZ 85040
|
|
|
TEST INFORMATION
|
|
Vial Number |
Vial Number |
|
|
1234568 |
1234567 |
|
Laboratory Information |
|
|
|
Log Number |
660411 |
660412 |
|
Date Received |
10/28/2005 |
10/28/2005 |
|
Date Analyzed |
10/29/2005 |
10/29/2005 |
|
Date Reported |
10/29/2005 |
10/29/2005 |
|
Exposure Period |
|
|
|
Start Time |
10/24/2005 13:30 |
10/24/2005 13:30 |
|
Finish Time |
10/27/2005 18:00 |
10/27/2005 18:00 |
|
Test Duration |
76.5 Hours |
76.5 Hours |
|
Test Location |
Basement |
Basement |
|
RESULTS |
2.1 pCi/L |
1.9 pCi/L |
|
|
|
|
|
AVERAGE: 2.0 pCi/L
|
Radon test results are below the EPA action level of 4.0 pCi/L No further action is required at this time. The EPA suggests that you may want to test again in the future to insure that radon levels remain below the action level.
This area reserved for additional State and Lab Comments
This report is not intended to provide medical or
healthcare advice. All medical-related questions and
concerns, including health concerns relating to
possible radon exposure, should be directed to a
qualified physician.
Report Reviewed By:
_______________________________________ __________________________________________________________________________________
Testing performed by: Accustar Labs, 11 Awl Street,
Medway, MA 02053
NEHA NRPP 101193 NRSB ARL0017 New Jersey
Certification # MA004 MEB 90122
NEHA Device Code 8088 EPA Method #402-R-93-004
Disclaimer: The uncertainty of this radon
measurement is .+/-10%. Factors contributing to
uncertainty include, statistical variations, daily
and seasonal variations in radon concentrations, and
operation of the dwelling. Interference with test
conditions may influence the test results.
This report may only be transferred to a third party
in its entirety. Results Shown on this report
represent levels of radon gas measured between the
dates shown in the room or area of the site
identified above as "Property Tested". Incorrect
information will affect results. The results may not
be construed as either predictive or supportive of
measurements conducted in any area of this structure
at any other time. AccuStar Labs, its employees and
agents are not responsible for the consequences of
any action taken or not taken based upon the results
reported or any verbal or written interpretation of
the results.
What your test results mean
The average indoor radon level is estimated to be
about 1.3 pCi/L, and about 0.4 pCi/L of radon is
normally found in the outside air. If the results of
your test show a radon level of approximately 4.0
pCi/L or higher the EPA recommends that you perform
a second short term test to verify the radon level.
If the second test results are equal to or higher
than the first, then you may be certain that you
have a radon problem and need to take action.
There are several methods that can be used to lower
radon levels in your home or office. Some techniques
prevent radon from entering your home while others
reduce radon levels after it has entered. The EPA
generally recommends methods which prevent the entry
of radon. Your state Radon Agency can provide you
with a number of references, resources and
licensed/certified contractors to evaluate your
problem and recommend a reduction method. The below
listed references may be used to learn more about
the Radon problem, remediate the problem within your
home or office and provide sources for additional
information. If you do not have internet access, the
state Radon Agencies phone numbers are listed in the
"Guide to the Dangers of Radon" booklet provided
with your Radon Test Kit.
|
|
Contacting H Chek, Inc
If you would like additional information related
to this Laboratory Report or a referral for
additional services please contact H Chek at:
|
E-mail: info@hchek.com
Toll Free: 866-234-7579
|
|
For Additional
Information on Radon please refer to the
following:
U.S. Environmental Protection Agency,
www.epa.gov/radon
U.S. Environmental Protection Agency, "Home
Buyer's and Seller's Guide to Radon",
www.epa.gov/radon/images/hmbuygud
U.S. Environmental Protection Agency, "A
Consumer's Guide to Radon Reduction",
www.epa.gov/radon/images/consguid
American Lung Association, www.lungusa.org
(Select Air Quality)
National Radon Safety Board, www.nrsb.org
For Regional and State Information please
refer to the following:
State and Regional Contact Information,
www.epa.gov/iaq/whereyoulive.html
EPA Map of Radon Zones, www.epa.gov/radon/zonemap.html
Terms, Conditions and Limitations
This report provides an initial indication of
indoor contaminants, based upon samples
collected by you.
H Chek, Inc. recommends that you not take any
actions based upon this report until you have
read the terms, conditions and limitations
described in this section.
Property conditions and laboratory results can
and do change over time. None of H Chek, Inc. or
its affiliates, subsidiaries, suppliers,
employees, agents, contractors and attorneys are
able to make and do not make any determinations
as to the safety or health condition of a
property in this report.
This report is not intended to provide medical
or healthcare advice. All radon or
medical-related questions and concerns,
including health concerns relating to possible
radon exposure, should be directed to a
qualified physician. If this report indicates
any findings that are of concern to you, further
evaluation by a trained professional may be
advisable.
Any delays in the shipping or receipt of the
Radon test sample shall be the sole
responsibility of the purchaser. Additionally, H
Chek shall not be responsible for the improper
placement of the test canisters, or liable for
results derived from the improper placement of
said test canister.
No H Chek related party shall have any liability
with respect to decisions or recommendations
made or actions taken by either the client or
professionals hired by the client, based upon
this report. In no event will any H Chek related
party be liable for any special, indirect,
incidental, punitive, or consequential damages
of any kind regardless of the form of action
whether in contract, tort (including
negligence), strict product liability or
otherwise, arising from or related to the
testing services or this report. The aggregate
liability of the H Chek related parties related
to or arising from this report, whether under
contract law, tort law, warranty or otherwise,
shall be limited to direct damages not to exceed
the fees actually received by H Chek from the
client for the report.
The invalidity or unenforceability, in whole or
in part, of any provision, term or condition
herein shall not invalidate or otherwise affect
the enforceability of the remainder of these
provisions, terms and conditions.
|
|
|
|